The effect of releasing critical pulleys of the fibrous sheath during flexor tendons repair in Kleinert–Verdan Zone II: a review

Andrzej Żyluk

Abstract


The fibrous flexor tendon sheath is a relatively thick structure surrounding both flexor tendons (superficial and profundus) along the finger and distal part of the metacarpus. It consists of circumferentially and obliquely passing bands, so-called ‘pulleys’. The flexor tendon fibrous sheath with its pulley system plays an important role in the proper gliding of the tendons by maintaining them close to the bone of phalanges during full finger flexion, and its major defects manifest by impaired flexion of the finger because the tendon bowstringing. There is no commonly accepted opinion about the range of pulley release which is safe and would not cause bowstringing. The article presents current recommendations about the safe range of release of pulleys during repair of the flexor tendons which essentially allows longer incisions than was suggested previously. The priority is the undisturbed gliding of repaired tendon along the finger and avoiding catching the repair at edge of the pulley, which would result in a reduction of the finger’s range of motion.

Keywords


fibrous flexor tendon sheath; flexor pulley system; venting of the fibrous sheath; bowstringing of the tendon

Full Text:

PDF

References


Tang JB, Lalonde D, Harhaus L, Sadek AF, Moriya K, Pan ZJ. Flexor tendon repair: recent changes and current methods. J Hand Surg Eur 2022;47(1):31-9.

Tang JB. Indications, methods, postoperative motion and outcome evaluation of primary flexor tendon repairs in Zone 2. J Hand Surg Eur 2007;32(2):118-29.

Elliot D, Giesen T. Primary flexor tendon surgery: the search for a perfect result. Hand Clin 2013;29(2):191-206.

Tang JB, Zhou X, Pan ZJ, Qing J, Gong KT, Chen J. Strong digital flexor tendon repair, extension-flexion test, and early active flexion: experi-ence in 300 tendons. Hand Clin 2017;33(3):455-63.

Tang JB. New developments are improving flexor tendon repair. Plast Reconstr Surg 2018;141(6):1427-37.

Moriya K, Yoshizu T, Tsubokawa N, Narisawa H, Hara K, Maki Y. Clinical results of releasing the entire A2 pulley after flexor tendon repair in zone 2c. J Hand Surg Eur 2016;41(8):822-8.

Moriya K, Yoshizu T, Tsubokawa N, Narisawa H, Hara K, Maki Y. Outcomes of release of the entire A4 pulley after flexor tendon repairs in zone 2A followed by early active mobilization. J Hand Surg Eur 2016;41(4):400-5.

Pan ZJ, Qin J, Zhou X, Chen J. Robust thumb flexor tendon repairs with a six-strand M-Tang method, pulley venting, and early active mo-tion. J Hand Surg Eur 2017;42(9):909-14.

Lalonde D, Martin A. Epinephrine in local anesthesia in finger and hand surgery: the case for wide-awake anesthesia. J Am Acad Orthop Surg 2013;21(8):443-7.

Lalonde D. Wide awake local anaesthesia no tourniquet technique (WALANT). BMC Proceedings 2015;Suppl 3:A81.

Żyluk A, Szlosser Z. Flexor tendon repair in local infiltration anaesthesia and a bloodless field – a case report. Pol Orthop Traumatol 2019;84(3):85-9.




DOI: https://doi.org/10.21164/pomjlifesci.886

Copyright (c) 2023 Andrzej Żyluk

License URL: https://creativecommons.org/licenses/by-nc-nd/3.0/pl/